Thank you for your interest in AM333HEMG6-15-250-400-14. Civil Aviation 360 offers an unmatched amount of premium NSN parts to various industries. Circuit Breaker is an item listed with the NSN 5925-00-403-4061 and is manufactured by Eaton Corp. If you are interested in beginning the purchasing process for this particular item AM333HEMG6-15-250-400-14, please finish filling out the provided Instant RFQ form with details like quantity and contact information. After submission, a staff member will contact you in 15 minutes or less with a personalized quote.
Civil Aviation 360 provides customers with a large inventory of NSN part such as AM333HEMG6-15-250-400-14 that are available for immediate purchase. A National Stock Number (NSN) is a number used to help classify items as they make their way through the federal supply system. Each NSN is unique, and the several digits describe different qualities like name, manufacturer, part number, and more. This classification system was created to eliminate confusion and duplication of orders, particularly in the United States Military Services. Since its first use after World War II, it has been officially recognized by the U.S. DOD and other NATO countries. For your convenience, 5925-00-403-4061 is also listed with its CAGE Code: 74193 and manufacturer: Eaton Corp. All items that Civil Aviation 360 provides come with expedited shipping and manufacturer trace documentation, as applicable.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-403-4061 Item Description: CIRCUIT BREAKER | 5925 | 004034061 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
AM333HEMG6-15-250-400-14 | 3 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT AND |
CQXF | Inclosure Protection Type For Which Designed | SALT SPRAY PROOF |
MRC | Decoded Requirement | Clear Text Reply |
BBRJ | Special Handling Feature | MAGNETIC |
CPLM | Maximum Continuous Load Current Rating Per Pole | 15.0 AMPERES AC ALL LOCATIONS |
CQXF | Inclosure Protection Type For Which Designed | MOISTURE RESISTANT AND |
AFJN | Fragility Factor | MODERATELY RUGGED |
THSD | Thread Series Designator | UNC |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
AEGJ | Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
TEST | Test Data Document | 13499-260-4015 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 6 THREADED HOLE |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
CQSM | Switch Location And Position Designation | INTERNAL AT POLE ONE |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 6 THREADED STUD |
AKPX | Pole Quantity | 3 |
CSSX | Switch Current Rating And Type In Amps | 1.0 DC |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.750 INCHES NOMINAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 115.0 ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CSSX | Switch Current Rating And Type In Amps | 2.5 AC AND |
AJEC | Boss Height | 0.140 INCHES NOMINAL |
CPRQ | Reset Method | MANUAL |
CPRW | Actuator Function | TRIP-RESET |
ADAT | Body Width | 2.250 INCHES NOMINAL |
CPRZ | Auxiliary Switch Function And Quantity | 1 ALARM |
ADTV | Case Material | PLASTIC |
CPRX | Actuator Position Designation | AT EACH POLE |
CSWP | Switch Voltage Rating And Type In Volts | 250.0 AC AND |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
AAJE | Thread Pitch Diameters | 0.1177 TO 0.1214 INCHES |
CSWP | Switch Voltage Rating And Type In Volts | 50.0 DC |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CRTK | Switch Terminal Type | TAB, SOLDER LUG |
CQJX | Nominal Thread Size | 0.138 INCHES |
AJWX | Mounting Surface To Terminal End Distance | 2.611 INCHES NOMINAL |
ADAQ | Body Length | 2.500 INCHES NOMINAL |
CMLP | Thread Quantity Per Inch | 32 |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.938 INCHES NOMINAL |
PKWT | Unpackaged Unit Weight | 14.250 OUNCES |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 20.000 MINIMUM AT 200 PCT AND |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 70.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CQXF | Inclosure Protection Type For Which Designed | SHOCK RESISTANT AND |
CQXF | Inclosure Protection Type For Which Designed | HUMIDITY RESISTANT AND |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.062 INCHES NOMINAL |